You are viewing the site in preview mode

Skip to main content

Table 3 Associations between covariates and abnormal RDS1.5 risk via univariate logistic regression analysis

From: Increasing myopic refraction reduces random dot stereopsis in Chinese myopic patients: a cross-sectional study

Variables

Normal

N = 154

Abnormal

N = 834

OR[95% CI]

P value

Sex

   

0.533

Male

77 (50.0%)

391 (46.9%)

Ref.

 

Female

77 (50.0%)

443 (53.1%)

1.13 [0.80;1.60]

 

Age (year)

25.8 ± 6.07

25.3 ± 6.20

0.99 [0.96;1.01]

0.308

Anisometropia (D)

0.52 ± 0.46

0.51 ± 0.46

0.99 [0.68;1.44]

0.959

SE (D)

4.69 ± 1.75

5.27 ± 2.00

1.17 [1.07;1.28]

<0.001

Astigmatism (D)

0.74 ± 0.52

0.95 ± 0.73

1.70 [1.25;2.30]

< 0.001

BCVA (LogMAR)

-0.02 ± 0.05

0.00 ± 0.02

196,218 [1394;27610908]

0.001

Myopia group

   

0.015

Mild myopia

22 (14.3%)

97 (11.6%)

Ref.

 

Moderate myopia

95 (61.7%)

436 (52.3%)

1.05 [0.61;1.72]

 

High myopia

37 (24.0%)

301 (36.1%)

1.85 [1.02;3.27]

 

Division

-7.43 ± 4.87

-7.58 ± 6.08

1.00 [0.96;1.03]

0.742

Fusion

4.13 ± 4.70

4.00 ± 4.93

0.99 [0.96;1.03]

0.765

PEP_Hori_Big

18.1 ± 35.00

23.4 ± 44.50

1.00 [1.00;1.01]

0.103

PEP_Vect_Big

4.65 ± 4.26

5.67 ± 5.00

1.06 [1.01;1.11]

0.009

PEP_Hori_Small

18.3 ± 29.80

30.8 ± 58.60

1.01 [1.00;1.01]

<0.001

PEP_Vect_Small

2.91 ± 3.96

4.05 ± 5.80

1.07 [1.01;1.13]

0.003

Fixational eye movement

0.317

Normal

114 (74.0%)

580 (69.6%)

Ref.

 

Abnormal

40 (26.0%)

253 (30.4%)

1.24 [0.85;1.85]

 

SNR

   

0.163

Normal

54 (43.2%)

204 (36.0%)

Ref.

 

Abnormal

71 (56.8%)

362 (64.0%)

1.35 [0.91;2.00]

 
  1. SE: all myopic values were reported as absolute values; BCVA: best-corrected visual acuity; LogMAR: logarithm of the minimum angle of resolution; mild myopia: SE >-3.00 D and ≤-0.50 D; moderate myopia: SE >-6.00 D and ≤-3.00 D; high myopia: SE ≤-6.00 D; PEP_Hori_Big: horizontal PEP (target 3°); PEP_Vect_Big: vertical PEP (target 3°); PEP_Hori_Small: horizontal PEP (target 1°); PEP_Vect_Small: vertical PEP (target 1°); SNR: signal-to-noise ratio; RDS1.5: stereopsis measured via random dot stereograms at 1.5 m from the screen