Table 2 Refractive results and visual acuity three months after implantation

From: Neurosensory binocular vision after bilateral implantation of an extended depth of focus intraocular lens with micro-monovision: a prospective cohort study

Parameter

EDOF group

Trifocal group

Bifocal group

P value

Monocular UDVA (logMAR)

0.11 ± 0.10

(0.16 ± 0.10)

0.12 ± 0.13

0.13 ± 0.13

0.850

Monocular CDVA (logMAR)

0.04 ± 0.07

0.02 ± 0.05c

0.08 ± 0.10b

0.001*

Postoperative cylinder (D)

−0.59 ± 0.42

−0.74 ± 0.47

−0.70 ± 0.49

0.226

Postoperative SEQ (D)

−0.51 ± 0.42

(−0.88 ± 0.53)

−0.27 ± 0.45c

−0.56 ± 0.56b

0.030*

Binocular UDVA (logMAR)

0.06 ± 0.08

0.05 ± 0.08

0.07 ± 0.12

0.709

Binocular UIVA (logMAR)

0.01 ± 0.07c

0.04 ± 0.08

0.07 ± 0.10a

0.031*

Binocular UNVA (logMAR)

0.12 ± 0.10

0.09 ± 0.11

0.08 ± 0.08

0.159

Binocular CDVA (logMAR)

0.03 ± 0.06

0.00 ± 0.05

0.05 ± 0.10

0.071

Binocular DCIVA (logMAR)

0.03 ± 0.07

0.07 ± 0.10

0.07 ± 0.08

0.147

Binocular DCNVA (logMAR)

0.20 ± 0.12b

0.08 ± 0.12a

0.12 ± 0.10

0.001*

  1. One-way ANOVA test or Kruskal–Wallis H test
  2. The contents in brackets represent the data of the nondominant eyes in the EDOF group
  3. CDVA Corrected distance visual acuity, D Diopter, EDOF Extended depth of focus, logMAR logarithm of the minimum angle of resolution, DCIVA Distance-corrected intermediate visual acuity, DCNVA Distance-corrected near visual acuity, SEQ Spherical equivalent, UDVA Uncorrected distance visual acuity, UIVA Uncorrected intermediate visual acuity, UNVA Uncorrected near visual acuity
  4. aP < 0.05 versus the EDOF group
  5. bP < 0.05 versus the trifocal group
  6. cP < 0.05 versus the bifocal group
  7. *P < 0.05 among three groups