Table 1 The objective assessment of the participants after wearing Somofilcon A contact lenses

From: Investigation of the influencing factors on subjective evaluation in initial and end-of-day silicone hydrogel contact lens wear

 

Somofilcon A

 

With lens

15 min

With lens

8 h

P-value

Residual refraction (D)

0.15 ± 0.45

0.01 ± 0.36

0.01*

Visual acuity (LogMAR)

-0.04 ± 0.07

-0.05 ± 0.07

0.21

F-NITBUT (s)

8.56 ± 7.12

10.88 ± 8.21

0.03*

A-NITBUT (s)

13.12 ± 6.91

16.48 ± 6.00

< 0.01**

  1. P-value calculated using the Friedman test (analysis of variance), **P < 0.01, *P < 0.05
  2. D, diopter; F-NITBUT, first noninvasive tear break-up time; A-NITBUT, average noninvasive tear break-up time; s, seconds