You are viewing the site in preview mode

Skip to main content

Investigation of the influencing factors on subjective evaluation in initial and end-of-day silicone hydrogel contact lens wear

Abstract

Background

This study aimed to investigate the factors influencing subjective ratings of comfort, vision quality, dryness, and satisfaction at both initial and end-of-day wear among young Asian wearers of silicone hydrogel contact lenses.

Methods

Participants aged 20 to 24 years who were satisfied wearers of silicone hydrogel daily disposable contact lenses were recruited. Each participant attended two scheduled visits. During the first visit (Day 1), ocular health, refractive error, visual acuity, first and average non-invasive tear break-up time (F-NITBUT and A-NITBUT), and subjective ratings were measured without lenses and 15 min after wearing Somofilcon A daily disposable lenses. On the second visit (Day 7), follow-up data were collected after seven consecutive days of lens wear.

Results

A total of 59 healthy participants (mean age: 20.86 ± 1.29 years) participated in this study. Visual acuity demonstrated a significant negative correlation with comfort, vision quality, and satisfaction after 15 min of Somofilcon A lens wear on Day 1 and a positive correlation with dryness. Additionally, A-NITBUT was significantly positively correlated with vision quality. On Day 7, visual acuity was negatively correlated with overall vision quality after 8 h of wear. However, residual refraction and F-NITBUT showed no significant correlation with comfort, vision quality, dryness, or satisfaction after 15 min of wear on Day 1–8 h on Day 7.

Conclusions

The results suggest that higher visual acuity at initial lens wear was strongly associated with improved subjective comfort, vision quality, and overall satisfaction, as well as reduced dryness. Furthermore, a longer average tear break-up time was associated with improved vision quality. For prolonged lens use, visual acuity was only associated with vision quality. Visual acuity plays a significant role in subjective ratings at the initial lens wear, while tear break-up time may serve as a predictor for subjective vision quality.

Peer Review reports

Background

Dryness, discomfort, and vision disturbances are among the primary causes of dissatisfaction and discontinuation of soft contact lens wear [1, 2] Principal reasons for discontinuation include distance vision blur, poor near vision, discomfort, and handling difficulties [3, 4, 5]. Considering the contact-lens-wearing experience, initial and end-of-day comfort are critical for soft contact lens tolerance and sustained use or discontinuation [6]. Recent reviews have identified strategies for improving comfort and mitigating dryness, such as switching lens materials [7, 8] and changing wear modality, [9] separately or in combination. Adjustments to the refractive power of contact lenses and changes in lens types are recommended to enhance visual clarity. Subjective comfort questionnaires are commonly employed by contact lens practitioners to identify dissatisfied wearers [10]. Other subjective methods include specialised visual acuity tests, contrast sensitivity tests, and assessments of visual function. Objective methods include ocular wavefront aberration analysis and tear stability analysis. These assessments provide insights into vision clarity, subjective comfort, and overall satisfaction following contact lens wear.

Over-refraction is a clinical method used to confirm changes in optical refraction during contact lens examinations and fittings [11]. This procedure allows practitioners to rapidly assess both spherical and astigmatic components of residual refractive error. Residual refractive error can degrade retinal image quality and negatively impact the vision of contact lens wearers. The refractive index and water content of contact lenses are interrelated [12] Dehydration, which alters the refractive index, can diminish lens performance and visual acuity and exacerbate discomfort [13]. The refractive index is a physical parameter that reflects the optical and physiological properties of the contact lens material and its equilibrium water content. As contact lenses dehydrate, surface irregularities may develop, inducing changes in refractive error after prolonged wear.

Contact lens water content influences vision, comfort, and optical quality, although its effect may be less pronounced in silicone hydrogel lenses. Silicone hydrogels typically exhibit less dehydration than traditional hydrogels and do not compromise oxygen performance; the silicone component of the lens primarily facilitates oxygen permeability [14, 15]. Some studies have reported that contact lens dehydration is a factor contributing to lens wear discontinuation [2, 16]. Severe dehydration in silicone hydrogel lenses can disrupt the ionic and hydraulic permeability of the lens material, particularly affecting lens movement and reducing comfort [15]. Lens diameter, [17] fit, [18] and oxygen transmissibility [15] may be altered by dehydration, leading to decreased lens comfort. Soft lenses change proportions, to some extent, on the eye, which can alter optical properties during wear. Previous studies have found a significant negative correlation between the extent of dehydration and subjective comfort ratings after 12 h of soft contact lens wear [10]. The tear film affects ocular optical quality as it constitutes the first refracting surface of the eye. Dry eye can impair visual functions, such as reading, [19, 20] digital device use, and driving [21]. Studies indicate that dry eye affects contrast sensitivity performance [22] and is associated with irregular astigmatism and higher-order optical aberrations [23]. However, the factors influencing subjective ratings during initial and end-of-day wear of silicone hydrogel contact lenses remain unclear. Therefore, this study aimed to investigate the factors influencing comfort, vision quality, dryness, and satisfaction in both initial and end-of-day wear of silicone hydrogel contact lenses.

Methods

Participants

This prospective, open-label study recruited satisfied wearers of silicone hydrogel daily disposable contact lenses (Somofilcon A) from Chung Shan Medical University and Da-Yeh University. The study adhered to the principles of the Declaration of Helsinki and received approval from the Human Research Ethics Committee of Chung Shan Medical University Hospital (No: CS1-22177). Informed consent was obtained from all participants after they understood the experimental procedure.

All the eligible participants (n = 59) were myopic Asians (≥ -6.00 diopters [D]) aged 20 to 24, capable of achieving a monocular habitual visual acuity of at least 20/25 using spherical soft contact lenses in both eyes. The participants had either normal or mild eye dryness (Ocular Surface Disease Index [OSDI] scores < 22), [24] were free from any ocular or systemic health conditions, and were not taking any medications. Additionally, inclusion in the study required spending more than 4 h per day viewing visual display terminals.

Experimental procedure

This study comprised two scheduled visits. During the first visit, the ocular surface was evaluated using slit lamp biomicroscopy (Topcon SL-D2; Tokyo, Japan), and baseline data, including spherical equivalent (SE) and keratometry, were measured using an autorefractor (Shin-Nippon NVision-K 5001; Osaka, Japan), for the uncorrected eyes. First, non-invasive tear break-up time (F-NITBUT) and average non-invasive tear break-up time (A-NITBUT) were measured using a Keratograph 5 M (Oculus Optikgerate, Wetzlar, Germany). Participants then wore Somofilcon A lenses for 15 min, and data on residual refraction, visual acuity, F-NITBUT, and A-NITBUT were collected. Residual refraction was measured using an autorefractor while participants wore the lenses. Visual acuity was measured at 6 m using a digital visual acuity chart system (VLC 1900-P, Seoul, Korea). Subjective ratings of comfort, vision quality, dryness, and satisfaction were assessed using a questionnaire after 15 min and 8 h of lens wear. Participants wore Somofilcon A lenses for 7 days, with daily lens replacements.

During the second visit, on the seventh day of Somofilcon A lens wear, participants underwent examinations for ocular surface health, residual refraction, visual acuity, F-NITBUT, and A-NITBUT after 8 h of lens wear. Subjective ratings of overall comfort, vision quality, lens dryness, and satisfaction were assessed using a questionnaire. Participants accessed the visual analogue scale (VAS) via an online platform during the study. All participants reported comfort scores ranging from 0 to 100, where 0 indicated “extremely uncomfortable” and 100 represented “extremely comfortable.” A score of 0 represented “not at all dry,” while 100 represented “extremely dry.”

Statistical analysis

G*Power software (version 3.1; Düsseldorf, Germany) was used to calculate the sample size for this study. The calculation was performed with α = 0.05 and included a 10% screening failure/dropout rate, resulting in a required minimum of 59 participants from two sites (Chung Shan Medical University and Da-Yeh University). Initially, 64 participants were recruited, but 5 were excluded for failing to meet the inclusion criteria. Ultimately, 59 eligible participants completed the study and were included in the analysis. All data were analysed using SPSS version 26 (IBM Corp, Armonk, NY). Only data from the right eye of each participant were included in the data analysis. The Friedman test was used to evaluate changes in residual refraction, visual acuity, F-NITBUT, and A-NITBUT while wearing Somofilcon A lenses. The Wilcoxon signed-rank test was used to compare subjective ratings after 15 min and 8 h of Somofilcon A lens wear. A linear regression model was used to assess the correlation of residual refraction between residual refraction subjective ratings of Somofilcon A lens wear and the correlation between residual refraction and visual acuity, F-NITBUT, and A-NITBUT. Data are expressed as median [interquartile range (IQR)], with a p-value of < 0.05 indicating statistical significance.

Results

Data collected from 59 participants (8 males and 51 females) were analysed, with a mean age of 20.86 ± 1.29 years (range: 20 to 24 years). The mean OSDI score was 6.93 ± 5.39, indicating that the participants did not exhibit dry eye symptoms. The mean spherical equivalent for the right eye was − 4.20 ± 1.65 D, and the mean keratometry was 43.57 ± 1.53 D. The mean of F-NITBUT and A-NITBUT were 12.14 ± 8.47 and 14.69 ± 7.33 s, respectively.

Table 1 presents the results of wearing Somofilcon A lenses. After 15 min of lens wear on Day 1, the mean residual refraction was 0.15 ± 0.45 D. This significantly decreased to 0.01 ± 0.36 D after 8 h of wear on Day 7 (P = 0.01). The F-NITBUT significantly increased from 8.56 ± 7.12 s after 15 min on Day 1 to 10.88 ± 8.21 s after 8 h on Day 7 (P < 0.01). Similarly, the A-NITBUT significantly increased from 13.12 ± 6.91 s to 16.48 ± 6.00 s after 15 min on Day 1 and 8 h of lens wear on Day 7 (P = 0.03). However, no significant difference in visual acuity was observed during Somofilcon A lens wear.

Table 1 The objective assessment of the participants after wearing Somofilcon A contact lenses

Table 2 presents subjective ratings of comfort, vision quality, dryness, and satisfaction at 15 min on Day 1 and after 8 h of wearing Somofilcon A lenses on Day 7. Comfort ratings significantly decreased from a median of 90.0 (IQR: 20.0) at 15 min to 89.0 (IQR: 10.0) after 8 h of wear (P = 0.034). Vision quality showed no statistically significant change. A significant increase in dryness was reported after 8 h, with median scores rising from 20.0 (IQR: 20.0) to 20.0 (IQR: 25.0; P = 0.006). Additionally, satisfaction ratings significantly decreased from a median of 90.0 (IQR: 15.0) at 15 min to 90.0 (IQR: 13.0) after 8 h of lens wear (P = 0.014).

Table 2 Median subjective ratings (1–100 numerical rating scale, 1-point increments) for Somofilcon A contact lens wearers

Table 3 presents the correlation between residual refraction, visual acuity, F-NITBUT, A-NITBUT, and subjective ratings. Residual refraction and F-NITBUT did not show significant correlations with comfort, vision quality, dryness, or satisfaction after 15 min of Somofilcon A lens wear on Day 1 and 8 h on Day 7. However, Fig. 1 illustrates that after 15 min of lens wear on Day 1, visual acuity was significantly negatively correlated with comfort (B = -59.97; 95% CI: -107.63 to -12.30), vision quality (B = -59.34; 95% CI: -97.68 to -21.15), and satisfaction (B = -47.43; 95% CI: -81.34 to -13.51), and significantly positively correlated with dryness (B = 55.05; 95% CI: 2.01 to 108.09). After 8 h of lens wear on Day 7, visual acuity was negatively correlated with overall vision quality (B = -40.46; 95% CI: -75.48 to -5.44). The A-NITBUT, after 15 min of Somofilcon A lens wear on Day 1, was significantly positively correlated with vision quality (B = 0.42; 95% CI: 0.03 to 0.81; Fig. 2).

Table 3 Linear regression model analysis to assess the correlation between residual refraction, visual acuity and subjective rating
Fig. 1
figure 1

Correlation between visual acuity (VA) and (A) comfort, (B) vision quality, (C) dryness, and (D) satisfaction after 15 min and 8 h of Somofilcon A lens wear

Fig. 2
figure 2

Correlation between the average noninvasive tear break-up time (A-NITBUT) and (A) comfort, (B) vision quality, (C) dryness, and (D) satisfaction after 15 min and 8 h of Somofilcon A lens wear

Discussion

Silicone hydrogel daily disposable contact lenses are continuously optimised to improve tear film stability and reduce discomfort. Although contact lens materials have continuously improved over the past five decades, ocular discomfort remains a primary factor contributing to dropout among contact lens wearers [25]. Despite these advancements, discontinuation of lens wear remains a common challenge, primarily due to dry-eye symptoms and end-of-day ocular discomfort [26, 27, 28]. This study evaluated factors influencing comfort, such as over-refraction, NITBUT, and visual acuity, at the initial 15-min wear and a 1-week follow-up among young adults using silicone hydrogel contact lenses.

The results showed a more pronounced negative change in residual refraction after 8 h of wear compared to 15 min with Somofilcon A lenses (0.15 ± 0.45 D vs. 0.01 ± 0.36 D, p = 0.01). Contact lens wear can increase permeability due to epithelial thinning, [29, 30] formation of epithelial microcysts, [25] and reduced cell adhesion [31]. These changes in refractive error may be attributed to epithelial alterations caused by hypoxia, lens pressure, and modulation of epithelial homeostasis during soft lens wear [32]. High-water-content hydrogel lenses tend to dehydrate more, leading to physiological changes [33]. Lens dehydration plays a crucial role in corneal epithelium integrity and can negatively affect lens comfort [10]. The degree and timeframe of lens dehydration depend on factors such as the polymer’s water content, lens thickness, temperature, humidity, and blink patterns [34, 35]. Reduced blinking while wearing high water content lenses is known to cause visual disturbances known as dehydration blur [36]. Additionally, decreased or incomplete blinking during prolonged digital screen use exacerbates tear film instability and increases visual aberrations [37, 38]. Dehydration-related alterations in the water content of contact lenses also change the refractive index, negatively affecting lens optics, visual acuity, and wearer comfort through refractive instability and visual degradation [13, 39].

In contrast, silicone hydrogel materials significantly improve oxygen permeability without increasing water content. Previous research demonstrated that in environments with 70% relative humidity and airflow, silicone hydrogel lenses experienced 10 − 20% dehydration.33 The most significant changes in relative humidity occurred within the first 15 min of exposure. This dehydration may lead to diminished lens performance, including increased visual aberrations, reduced visual acuity, and greater deposition of tear film components [39, 40].

NITBUT is essential for maintaining visual clarity, particularly during prolonged digital device use [41]. If tear film stability is compromised, complications may arise [42, 43]. Colak et al. recruited 50 silicone hydrogel contact lens wearers and 50 non-wearers to evaluate the effects of silicone hydrogel lenses on ocular surface parameters. Their results demonstrated significantly shorter NITBUT values, along with higher corneal fluorescein staining, OSDI scores, and meiboscores in contact lens wearers compared to non-wearers [44]. Extended video display terminal use is a major risk factor for dry eye disease due to decreased blink rates and increased tear evaporation [45]. In the current study, both F-NITBUT and A-NITBUT significantly increased after 8 h of Somofilcon A lens wear compared to initial measurements at 15 min (p = 0.03 and p < 0.01, respectively). Although the F-NITBUT was ˂ 10 s during the initial 15 min of wear, it increased to ˃ 10 s after 8 h, suggesting the potential for sustained visual quality. These findings align with those of Varikooty et al., who investigated the clinical performance and physiological responses in silicone hydrogel contact lens wearers. Their study similarly reported stable tear break-up times after 8 h of silicone hydrogel daily disposable lens wear. Additionally, no significant differences were found between asymptomatic (n = 51) and symptomatic (n = 53) participants regarding pre-lens NITBUT, deposit rate, wettability, lens movement, bulbar or limbal redness, and corneal or conjunctival staining [46].

Several factors can influence ocular comfort, including environmental conditions, ocular health, and the material properties of contact lenses. In this study, subjective ratings of comfort, dryness, and overall satisfaction progressively decreased with longer wear times (Table 2), a finding consistent with other research showing a decline in comfort during extended soft lens usage [47, 48, 49]. However, a previous study indicated that a reduction in comfort was also observed in asymptomatic individuals not wearing contact lenses by the end of the day [50]. Contact lens materials can affect the tear film by increasing evaporation rates and reducing tear thinning time, [51] which may explain the significant increase in dryness observed after 8 h of wear in this study (Table 2). While evaporation can contribute to dryness, the sensory nerves on the ocular surface are stimulated to produce more tear fluid, resulting in increased tear production [52]. This may explain the significant increase in F-NITBUT and A-NITBUT after 8 h of wear (Table 1). Although dryness increased with prolonged wear, visual acuity did not decrease, which may be attributed to the stability of the tear film.

A key finding was that visual acuity significantly influenced subjective visual quality at the initial wear of the lenses and after 8 h of wear. The results indicated that better visual acuity was associated with lower levels of dryness and higher subjective comfort, vision quality, and satisfaction after the initial lens wear (Table 3). Additionally, a higher subjective vision quality level was significantly correlated with longer A-NITBUT at the initial wear. After 8 h, better visual acuity was significantly correlated only with a higher level of subjective visual quality. Previous studies suggest that better tear film quality improves vision quality. Another key finding was that the compensatory response to dryness might increase tear fluid production, which, in turn, extends tear break-up time and potentially helps to maintain vision quality. [53].

This study has some limitations. First, the participants recruited did not have dry eye disease, so the results only reflect subjective outcomes from individuals without dry eye conditions. Additionally, the duration of contact lens wear was 8 h, whereas extended wear typically exceeds 12 h.

Conclusions

Our findings demonstrated that visual acuity at initial lens wear was strongly associated with subjective comfort, vision quality, dryness, and overall satisfaction, while average tear break-up time was correlated with vision quality. However, after 8 h of wear, visual acuity was only associated with vision quality. In summary, visual acuity is a key factor for subjective comfort at initial wear and tear break-up time and may serve as a predictor for subjective vision quality. These findings may aid eye care professionals in reducing contact lens discontinuation.

Data availability

No datasets were generated or analysed during the current study.

Abbreviations

F-NITBUT:

First noninvasive tear break-up time

A-NITBUT:

Average noninvasive tear break-up time

OSDI:

Ocular Surface Disease Index

SE:

Spherical equivalent

VAS:

Visual analog scale

D:

Diopter

IQR:

Interquartile range

NITBUT:

Noninvasive tear break-up time

References

  1. Dumbleton K, Woods CA, Jones LW, Fonn D. The impact of contemporary contact lenses on contact lens discontinuation. Eye Contact Lens. 2013;39(1):93–9. Epub 2012/12/26.

    Article  PubMed  Google Scholar 

  2. Young G, Veys J, Pritchard N, Coleman S. A multi-centre study of lapsed contact lens wearers. Ophthalmic Physiol Opt. 2002;22(6):516–27. Epub 2002/12/13.

    Article  PubMed  Google Scholar 

  3. Sulley A, Young G, Hunt C. Factors in the success of new contact lens wearers. Cont Lens Anterior Eye. 2017;40(1):15–24. Epub 2016/11/08.

    Article  PubMed  Google Scholar 

  4. Stapleton F, Bakkar M, Carnt N, et al. CLEAR - Contact lens complications. Cont Lens Anterior Eye. 2021;44(2):330–67. Epub 2021/03/30.

    Article  PubMed  Google Scholar 

  5. Gantz L, Weissman BA, Ifrah R. Complications and compliance in professionally-managed and self-managed contact lenses compared with non-contact lens wearers. PLoS ONE. 2024;19(9):e0308538. Epub 2024/09/06.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  6. McMonnies CW. An amplifying cascade of contact Lens-Related End-of-Day hyperaemia and dryness symptoms. Curr Eye Res. 2018;43(7):839–47. Epub 2018/04/10.

    Article  PubMed  Google Scholar 

  7. Naidoo KS, Jaggernath J. Uncorrected refractive errors. Indian J Ophthalmol. 2012;60(5):432–7. Epub 2012/09/05.

    Article  PubMed  PubMed Central  Google Scholar 

  8. Chalmers R, Long B, Dillehay S, Begley C. Improving contact-lens related dryness symptoms with silicone hydrogel lenses. Optom Vis Sci. 2008;85(8):778–84. Epub 2008/08/05.

    Article  PubMed  Google Scholar 

  9. Fahmy M, Long B, Giles T, Wang CH. Comfort-enhanced daily disposable contact lens reduces symptoms among weekly/monthly wear patients. Eye Contact Lens. 2010;36(4):215–9. Epub 2010/06/15.

    Article  PubMed  Google Scholar 

  10. Hall B, Jones S, Young G, Coleman S. The on-eye dehydration of proclear compatibles lenses. Clao J. 1999;25(4):233–7. Epub 1999/11/11.

    PubMed  CAS  Google Scholar 

  11. Strang NC, Gray LS, Winn B, Pugh JR. Clinical evaluation of infrared autorefractors for use in contact lens over-refraction. Cont Lens Anterior Eye. 1997;20(4):137–42. Epub 1997/01/01.

    Article  PubMed  CAS  Google Scholar 

  12. González-Méijome JM, Lira M, López-Alemany A, Almeida JB, Parafita MA, Refojo MF. Refractive index and equilibrium water content of conventional and silicone hydrogel contact lenses. Ophthalmic Physiol Opt. 2006;26(1):57–64. Epub 2006/01/05.

    Article  PubMed  Google Scholar 

  13. Lira M, Santos L, Azeredo J, Yebra-Pimentel E, Real Oliveira ME. The effect of lens wear on refractive index of conventional hydrogel and silicone-hydrogel contact lenses: a comparative study. Cont Lens Anterior Eye. 2008;31(2):89–94. Epub 2007/10/30.

    Article  PubMed  CAS  Google Scholar 

  14. González-Méijome JM, López-Alemany A, Almeida JB, Parafita MA, Refojo MF. Qualitative and quantitative characterization of the in vitro dehydration process of hydrogel contact lenses. J Biomed Mater Res B Appl Biomater. 2007;83(2):512–26. Epub 2007/05/02.

    Article  PubMed  Google Scholar 

  15. Morgan PB, Efron N. In vivo dehydration of silicone hydrogel contact lenses. Eye Contact Lens. 2003;29(3):173–6. Epub 2003/07/16.

    Article  PubMed  Google Scholar 

  16. Pritchard N, Fonn D, Brazeau D. Discontinuation of contact lens wear: a survey. Int Contact Lens Clin. 1999;26(6):157–62. Epub 2001/06/01.

    Article  PubMed  CAS  Google Scholar 

  17. Young G, Garofalo R, Peters S, Harmer O. The effect of temperature on soft contact lens modulus and diameter. Eye Contact Lens. 2011;37(6):337–41. Epub 2011/09/10.

    Article  PubMed  Google Scholar 

  18. Jones L, May C, Nazar L, Simpson T. In vitro evaluation of the dehydration characteristics of silicone hydrogel and conventional hydrogel contact lens materials. Cont Lens Anterior Eye. 2002;25(3):147–56. Epub 2005/11/24.

    Article  PubMed  CAS  Google Scholar 

  19. Akpek EK, Karakus S, Ramulu PY, Mathews PM. Sustained gazing causes measurable decline in visual function of patients with dry eye. Am J Ophthalmol. 2020;210:107–15. Epub 2019/10/14.

    Article  PubMed  Google Scholar 

  20. Goto E, Yagi Y, Matsumoto Y, Tsubota K. Impaired functional visual acuity of dry eye patients. Am J Ophthalmol. 2002;133(2):181–6. Epub 2002/01/29.

    Article  PubMed  Google Scholar 

  21. Negishi K, Masui S, Mimura M, Fujita Y, Tsubota K. Relationship between functional visual acuity and useful field of view in elderly drivers. PLoS ONE. 2016;11(1):e0147516. Epub 2016/01/26.

    Article  PubMed  PubMed Central  Google Scholar 

  22. Szczotka-Flynn LB, Maguire MG, Ying GS, et al. Impact of dry eye on visual acuity and contrast sensitivity: dry eye assessment and management study. Optom Vis Sci. 2019;96(6):387–96. Epub 2019/05/23.

    Article  PubMed  PubMed Central  Google Scholar 

  23. Koh S. Irregular astigmatism and Higher-Order aberrations in eyes with dry eye disease. Invest Ophthalmol Vis Sci. 2018;59(14):Des36–40. Epub 2018/11/28.

    Article  PubMed  Google Scholar 

  24. Schiffman RM, Christianson MD, Jacobsen G, Hirsch JD, Reis BL. Reliability and validity of the ocular surface disease index. Arch Ophthalmol. 2000;118(5):615–21. Epub 2000/05/18.

    Article  PubMed  CAS  Google Scholar 

  25. Grant T, Tang A. A survey of contact Lens wearers and eye care professionals on satisfaction with a new Smart-Surface silicone hydrogel daily disposable contact Lens. Clin Optom (Auckl). 2020;12:9–15. Epub 2020/02/06.

    Article  PubMed  Google Scholar 

  26. Dumbleton KA, Guillon M, Theodoratos P, Patel T. Diurnal variation in comfort in contact Lens and Non-contact Lens wearers. Optom Vis Sci. 2016;93(8):820–7. Epub 2016/07/01.

    Article  PubMed  Google Scholar 

  27. Guillon M, Dumbleton KA, Theodoratos P, et al. Association between contact Lens discomfort and Pre-lens tear film kinetics. Optom Vis Sci. 2016;93(8):881–91. Epub 2016/04/20.

    Article  PubMed  Google Scholar 

  28. Rohit A, Willcox M, Stapleton F. Tear lipid layer and contact lens comfort: a review. Eye Contact Lens. 2013;39(3):247–53. Epub 2013/04/16.

    Article  PubMed  Google Scholar 

  29. McNamara NA, Polse KA, Fukunaga SA, Maebori JS, Suzuki RM. Soft lens extended wear affects epithelial barrier function. Ophthalmology. 1998;105(12):2330–5. Epub 1998/12/17.

    Article  PubMed  CAS  Google Scholar 

  30. Humphreys JA, Larke JR, Parrish ST. Microepithelial cysts observed in extended contact-lens wearing subjects. Br J Ophthalmol. 1980;64(12):888–9. Epub 1980/12/01.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  31. Madigan MC, Holden BA. Reduced epithelial adhesion after extended contact lens wear correlates with reduced hemidesmosome density in Cat cornea. Invest Ophthalmol Vis Sci. 1992;33(2):314–23. Epub 1992/02/01.

    PubMed  CAS  Google Scholar 

  32. Jalbert I, Sweeney DF, Stapleton F. The effect of long-term wear of soft lenses of low and high oxygen transmissibility on the corneal epithelium. Eye (Lond). 2009;23(6):1282–7. Epub 2008/10/14.

    Article  PubMed  CAS  Google Scholar 

  33. Martín-Montañez V, López-Miguel A, Arroyo C, et al. Influence of environmental factors in the in vitro dehydration of hydrogel and silicone hydrogel contact lenses. J Biomed Mater Res B Appl Biomater. 2014;102(4):764–71. Epub 2013/10/22.

    Article  PubMed  Google Scholar 

  34. Efron N, Brennan NA, Bruce AS, Duldig DI, Russo NJ. Dehydration of hydrogel lenses under normal wearing conditions. Clao J. 1987;13(3):152–6. Epub 1987/05/01.

    PubMed  CAS  Google Scholar 

  35. Andrasko G. The amount and time course of soft contact lens dehydration. J Am Optom Assoc. 1982;53(3):207. Epub 1982/03/01.

    PubMed  CAS  Google Scholar 

  36. Keeney AH, Shrader EC. Kinetic visual disturbances with contact lenses. Surv Ophthalmol. 1983;28(2):112–6. Epub 1983/09/01.

    Article  PubMed  CAS  Google Scholar 

  37. Cardona G, García C, Serés C, Vilaseca M, Gispets J. Blink rate, Blink amplitude, and tear film integrity during dynamic visual display terminal tasks. Curr Eye Res. 2011;36(3):190–7. Epub 2011/02/01.

    Article  PubMed  Google Scholar 

  38. Jansen ME, Begley CG, Himebaugh NH, Port NL. Effect of contact lens wear and a near task on tear film break-up. Optom Vis Sci. 2010;87(5):350–7. Epub 2010/03/31.

    Article  PubMed  Google Scholar 

  39. Tranoudis I, Efron N. In-eye performance of soft contact lenses made from different materials. Cont Lens Anterior Eye. 2004;27(3):133–48. Epub 2005/11/24.

    Article  PubMed  Google Scholar 

  40. Ramamoorthy P, Sinnott LT, Nichols JJ. Contact lens material characteristics associated with hydrogel lens dehydration. Ophthalmic Physiol Opt. 2010;30(2):160–6. Epub 2010/05/07.

    Article  PubMed  Google Scholar 

  41. Xi L, Qin J, Bao Y. Assessment of tear film optical quality in a young short tear break-up time dry eye: Case-control study. Med (Baltim). 2019;98(40):e17255. Epub 2019/10/03.

    Article  Google Scholar 

  42. Korb DR, Greiner JV, Glonek T. Tear film lipid layer formation: implications for contact lens wear. Optom Vis Sci. 1996;73(3):189–92. Epub 1996/03/01.

    Article  PubMed  CAS  Google Scholar 

  43. Guillon M, Styles E, Guillon JP, Maïssa C. Preocular tear film characteristics of nonwearers and soft contact lens wearers. Optom Vis Sci. 1997;74(5):273–9. Epub 1997/05/01.

    Article  PubMed  CAS  Google Scholar 

  44. Colak D, Kocabeyoglu S, Karakaya J, Irkec M. Association of ocular surface and meibomian gland alterations with silicone hydrogel contact lens wear. Cont Lens Anterior Eye. 2024;47(1):102093. Epub 2023/11/12.

    Article  PubMed  Google Scholar 

  45. Craig JP, Willcox MD, Argüeso P et al. The TFOS International Workshop on Contact Lens Discomfort: report of the contact lens interactions with the tear film subcommittee. Invest Ophthalmol Vis Sci. 2013;54(11):Tfos123-56. Epub 2013/09/24.

  46. Varikooty J, Schulze MM, Dumbleton K, et al. Clinical performance of three silicone hydrogel daily disposable lenses. Optom Vis Sci. 2015;92(3):301–11. Epub 2015/01/30.

    Article  PubMed  Google Scholar 

  47. Fernández-Jimenez E, Diz-Arias E, Peral A. Improving ocular surface comfort in contact lens wearers. Cont Lens Anterior Eye. 2022;45(3):101544. Epub 2021/11/30.

    Article  PubMed  Google Scholar 

  48. Keir N, Woods CA, Dumbleton K, Jones L. Clinical performance of different care systems with silicone hydrogel contact lenses. Cont Lens Anterior Eye. 2010;33(4):189–95. Epub 2010/03/06.

    Article  PubMed  Google Scholar 

  49. Epstein AB. Contact lens care products effect on corneal sensitivity and patient comfort. Eye Contact Lens. 2006;32(3):128–32. Epub 2006/05/17.

    Article  PubMed  Google Scholar 

  50. Masoudi S, Zhao Z, Stapleton F, Willcox M. Contact Lens-Induced discomfort and inflammatory mediator changes in tears. Eye Contact Lens. 2017;43(1):40–5. Epub 2016/01/26.

    Article  PubMed  Google Scholar 

  51. Thai LC, Tomlinson A, Doane MG. Effect of contact lens materials on tear physiology. Optom Vis Sci. 2004;81(3):194–204. Epub 2004/03/17.

    Article  PubMed  Google Scholar 

  52. Monfared N, Murphy PJ. Features and influences on the normal tear evaporation rate. Cont Lens Anterior Eye. 2023;46(2):101809. Epub 2023/01/10.

    Article  PubMed  Google Scholar 

  53. Arita R, Morishige N, Koh S, et al. Increased tear fluid production as a compensatory response to meibomian gland loss: A multicenter Cross-sectional study. Ophthalmology. 2015;122(5):925–33. Epub 2015/01/30.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors thank all the participants for their cooperation.

Funding

This study was funded by a grant from the National Science and Technology Council (NSTC 112-2314-B-212-001). The funding organization had no role in the design or conduct of this research, nor in the decision to submit the manuscript for publication.

Author information

Authors and Affiliations

Authors

Contributions

HS designed the study protocol and prepared the final manuscript. RY recruited the subjects and preformed the statistical analysis. YC conducted the study and prepared the final manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Ya-Yu Chen.

Ethics declarations

Ethics approval and consent to participate

This study adhered to the tenets of the Declaration of Helsinki and received ethical clearance from the Human Research Ethics Committee of Chung Shan Medical University Hospital (No: CS1-22177, approval date: January 18, 2023). Written informed consent was obtained from all subjects.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sun, HY., Yang, RY. & Chen, YY. Investigation of the influencing factors on subjective evaluation in initial and end-of-day silicone hydrogel contact lens wear. BMC Ophthalmol 25, 287 (2025). https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12886-025-04110-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doiorg.publicaciones.saludcastillayleon.es/10.1186/s12886-025-04110-y

Keywords